Measured Components Dust, Opacity Measurement Principles Laser (Optical transmission method)
Measuring Range
Dust Min 0-1000 / Max 0-20000 mg/m3
Opacity 0-100% Min. Distance
0.1 mg/m3 Accuracy
〈 ±0.5% FS
Zero Drift (24 hours) 〈 ± 1% FS Span Drift (24 hours) 〈 ± 2% FS
Repeatability 〈 ± 1% FS Linearity
〈 ± 2% FS
Response Time 〈 5 seconds Enclosure Rating IP65 (Analyzer Panal)
Certicicates / Approvals
-
Type Approval (Korea)
-
-
System Components
-
Transceiver Unit, Probe Unit
Reflector Unit
Analyzer Unit / Cables
Master Flange / Air Purge Unit
Features
-
Probe type allows stable measurement in high concentration
-
Double Path measurement with measuring probe allows stability under vibration or distortion
-
Improved durability with patented probe protector
Options
-
Calibration Zig
-
Main Unit Cabinet
-
Higher Enclosure or Protection Level
-
-
Measurement Conditions
Operating Temperature -20 ~ +55 ℃
Operating Pressure 3 bar (≒ 300 kPa) Operating Humidity 0 ~ 95% RH Gas Temperature -30 ~ +300 °C Gas Pressure -50 ~ 30 hPa Communication
Analog Outputs 1 Channel, 4 ~ 20mA Digital Outputs 3 Channel
Digital Inputs 1 Channel / DI Voltage 12 VDC~24 VDC Display & Input Device 7" LCD touch panel(Touch screen / USB) Interface RS232,422,485 / TCP-IP Via Ethernet / Hart -
Dimension & Power Supply (Analyzer Unit)
Materials SUS 304 Voltage 100 ~ 220 VAC, 50/60 Hz Power Consumption 200 W (Max.) Dimension W400 x D201 x H500 mm Weight 18.5 kg Dimension & Power Supply (Probe Unit)
Materials SUS 316, SUS 316Ti Dimension 0.5 ~ 2.5 m Weight 10 ~ 20 kg Dimension & Power Supply (Purge Air Unit)
Dimension W550 x D350 x H850 mm Weight 15kg Voltage 3P 480VAC or 1P 220VAC Power Consumption 1.0kW ~ 1.5 kW